Density grades
12 density grades of stone wool board, each with its models, CE thickness window, DoP, measured thermal conductivity, fire class and papers by market.
Paper matrix
One row per grade. Each cell names a paper and links to it.
- CE certificate 2649-CPR-26000401 covers 40, 60, 80, 100, 110, 120, and 140 kg/m³, at thicknesses within 50–200 mm.
- CE certificate 2649-CPR-26000401 covers 160 kg/m³, at thicknesses within 50–150 mm.
- CE certificate 2649-CPR-26000401 covers 180 kg/m³, at thicknesses within 50–100 mm.
40 kg/m³
- Models and thickness
- Thermal conductivity
0.035 W/(m·K), measured under EN 12667:2001 on a 50 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Reports at this density: 251202026SHF-001, 251202026SHF-002
60 kg/m³
- Models and thickness
- Thermal conductivity
0.032 W/(m·K), measured under EN 12667:2001 on a 60 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
80 kg/m³
- Models and thickness
- TSW80 Taishi® Roof Insulation Board, factory thickness 30–200 mm
- TSM80 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
- TSX80 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
- TSD80 Taishi® Multipurpose Stone Wool Board, factory thickness 30–200 mm
- TSC80 Taishi® Marine Insulation Stone Wool Board, factory thickness 30–150 mm
- TSFB80 Taishi® Fireproof Black Stone Wool Board, factory thickness 100 mm
- Thermal conductivity
0.031 W/(m·K), measured under EN 12667:2001 on a 80 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Reports at this density: XJ2026B03D02237, SHFS2401000126FF
Certificates: CCS Works Approval
- Other EN properties
100 kg/m³
- Models and thickness
- TSS100 Taishi® Vertical Wall Insulation Strip, factory thickness 30–200 mm
- TSM100 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
- TSX100 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
- TSF100 Taishi® Composite Slab Stone Wool Board, factory thickness 100 mm
- TSD100 Taishi® Multipurpose Stone Wool Board, factory thickness 50–100 mm
- TSFB110 Taishi® Fireproof Black Stone Wool Board, factory thickness 100 mm
- Thermal conductivity
0.031 W/(m·K), measured under EN 12667:2001 on a 100 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Reports at this density: WSW 25030179
110 kg/m³
- Models and thickness
- Thermal conductivity
0.031 W/(m·K), measured under EN 12667:2001 on a 120 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
120 kg/m³
- Models and thickness
- TSM120 Taishi® Curtain Wall Insulation Board, factory thickness 30–100 mm
- TSX120 Taishi® Sandwich Panel Core Stone Wool, factory thickness 30–200 mm
- TSF120 Taishi® Composite Slab Stone Wool Board, factory thickness 100 mm
- TSD120 Taishi® Multipurpose Stone Wool Board, factory thickness 50–100 mm
- TSC120 Taishi® Marine Insulation Stone Wool Board, factory thickness 30–150 mm
- TSCL120 Taishi® Marine Insulation Stone Wool Board, factory thickness 48.5–100 mm
- Thermal conductivity
0.034 W/(m·K), measured under EN 12667:2001 on a 150 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Certificates: CCS Works Approval, GOST Fire Safety (Russia)
140 kg/m³
- Models and thickness
- Thermal conductivity
0.034 W/(m·K), measured under EN 12667:2001 on a 200 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Reports at this density: SHFS2401000125FF
- Other EN properties
150 kg/m³
- Models and thickness
- TSCL150 Taishi® Marine Insulation Stone Wool Board, factory thickness 48.5–100 mm
- Reaction to fire
Certificates: CCS Works Approval
160 kg/m³
- Models and thickness
- Thermal conductivity
0.034 W/(m·K), measured under EN 12667:2001 on a 30 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Certificates: CCS Works Approval
180 kg/m³
- Models and thickness
- Thermal conductivity
0.037 W/(m·K), measured under EN 12667:2001 on a 100 mm specimen.
CTC Nanjing Guocai Testing Co., Ltd., CMA 230010260188 · CNAS L0846 · ilac-MRA.
- Reaction to fire
Class A1 under EN 13501-1, on the CE certificate.
Classification reports: 251202026SHF-003 (40 kg/m³), 251202026SHF-006 (180 kg/m³)
Reports at this density: 251202026SHF-004, 251202026SHF-005
200 kg/m³
- Models and thickness
- Reaction to fire
Certificates: CCS Works Approval
220 kg/m³
- Models and thickness
- TSCL220 Taishi® Marine Insulation Stone Wool Board, factory thickness 23–100 mm
Quote by density grade
Name the grade, the thickness and the quantity. We reply with the price and the papers for that grade.